Low Pressure Installations


Download as PDF



Download as PDF

Installation to comply with NZBC Clause G12 (2001) or NZS 4607:1989

Acceptable solution G12/AS1

States that hot and cold water supply systems when outside the building thermal envelope shall be protected from freezing. (refer G12 clause  7.2.1 and AS/NZS 3500)

Therefore it essential that all Apex valves outside the building thermal envelope must also be protected from freezing and it is recommended best practise that valves are installed WITHIN a building thermal envelope.


Notes:

* R.V and E.V drains may be combined provided discharge is via a minimum air break of 25mm. Drain must have a minimum size of 20mm diameter and be one size larger then the largest relief valve outlet..

** 1.0m minimum copper pipe length from cylinder to Tempering Valve