Frequently Asked Questions
 |
Do you have a technical question you would like answered?"
If you have a technical or product related question of any type, then please email us on
technical@apexvalves.co.nz and we will reply to
your email personally and then add it to the Q & A section below to allow others to benefit from your question. |
 |
 |
 |
Q. Where is the best place to
install the Filterstop?
A. Ideally, the valve should be fitted in a position so as to protect all
downstream tapware and fittings, therefore where the main enters the building is the best place to install
the valve. The valve may also be installed in any orientation although Apex recommends the filter bowl (cap)
down so that any sediment is easily cleaned out.
Q. Can the
Limiting Valve be installed in the ground?
A. No, the valve must be open to atmosphere, installing in the ground may
result in reduced flow rates.
Q. Can the
Relief Valve be installed on it's side?
A. Yes, as long as the relief drain falls continuously to the outlet.
Q. Can valves cause water hammer?
A. No. Shut off devises such as single lever taps and solenoid valves are
the cause. The water hammer is arrested at the
non-return and the next upstream valve. A water hammer arrester at the source will prevent this. |
|
|
|