Application
High (mains) pressure systems.
Video
 |
Limiting Stop Valve. |
| Run-time: 50 seconds |
 |
|
Requires Windows Media Player to be installed.
Standards
- Complies with NZ Building Code G12 (2001)
- Complies with NZS 4608
- Patent No. 280678
- LVA - AS1357.2-1998, Lic. 2596
- LVRA20 - AS1357.2 Lic. 2596
Specifications
| LV15 |
Inlet |
15mm, 1/2" BSP (male) |
| Outlet |
20mm, 3/4" BSP (male) |
| LV20 |
Inlet |
20mm, 3/4" BSP (female) |
| Outlet |
20mm, 3/4" BSP (male) |
| LVT15 |
Inlet |
15mm, 1/2" BSP (male) |
| Outlet |
20mm, 3/4" BSP (male) |
| LVT20 |
Inlet |
20mm, 3/4" BSP (female) |
| Outlet |
20mm, 3/4" BSP (male) |
| LV25 |
Inlet |
25mm, 1" BSP (male) |
| Outlet |
25mm, 1" BSP (male) |
| LSV20 |
Inlet |
20mm, 3/4" BSP (male) |
| Outlet |
20mm, 3/4" BSP (male) |
| LVA |
Inlet |
20mm, 3/4" BSP (female) |
| Outlet |
20mm, 3/4" BSP (male) |
| LVRA |
Inlet |
20mm, 3/4" BSP (female) |
| Outlet |
20mm, 3/4" BSP (male) |
| Length |
LV (all models except LV25) |
80mm |
| LV25 |
110mm |
| LSV |
140mm |
| LVRA |
70mm |
- Maximum inlet pressure: 1600 kPa [230 P.S.I.] (LV25 up to 2000 kPa).
- Maximum temperature: 65°C.
- Pressure compensated to give constant outlet pressure regardless of inlet pressure.
- Adjustable outlet pressure: 200 - 600 kPa [29 - 87 P.S.I.].
- Removable cartridge for easy servicing.
- Integral 60 mesh (250 micron) filter.
- DR (Dezincification Resistant) brass.
Flow Chart
Installation
- Refer to Technical Area
for installation guide.
- Do NOT install Limiting Valve in the ground.
- Do NOT apply heat near valve during installation.
- Install so that both hot and cold supplies are balanced.
- Can be installed in any orientation. For external application, cartridge must be at
bottom.
- Must be installed with correct Expansion Valve fitted down stream of a limiting valve.
- To adjust outlet pressure use large Philips/Pozi screw driver, turn adjusting screw
clockwise to increase (1 turn = 60 kPa [9 P.S.I.]).
Removable Cartridge
- All valve seats are contained within cartridge.
- No need to remove body from valve train.
- Unscrew cartridge to replace or clean filter.
- Removal of cartridge will not affect set pressure.
Sectional Views
| Pressure Limiting (LV-15 & LV-20) |
 |
| Pressure Limiting (LV-25 only) |
 |
| Pressure Limiting Stop Valve (LSV) |
 |
| Pressure Limiting Replaceable (LVRA) |
 |
|
|
 |
 |
 |




Brochure
Download the new LV25 Pressure Limiting Valve brochure as a PDF* or contact us to have one sent to you.

Download as PDF

*Requires Adobe Acrobat Reader to be installed.
Product Codes
| LV15-350 |
350 kPa |
Use with EVT500 |
| LV15-500 |
500 kPa |
Use with EVT700 |
| LV20-350 |
350 kPa |
Use with EVT500 |
| LV20-500 |
500 kPa |
Use with EVT700 |
| LV25-500 |
500 kPa |
Use with EVT700 |
| LVT15-350 |
350 kPa |
Use with EVT500 |
| LVT15-500 |
500 kPa |
Use with EVT700 |
| LVT20-350 |
350 kPa |
Use with EVT500 |
| LVT20-500 |
500 kPa |
Use with EVT700 |
| LSV20-350 |
350 kPa |
Use with EVT500 |
| LSV20-500 |
500 kPa |
Use with EVT700 |
| LVA20-350 |
350 kPa |
Use with 500 kPa Expansion Control Valve |
| LVA20-500 |
500 kPa |
Use with 850 kPa Expansion Control Valve |
| LVA20-600 |
600 kPa |
Use with 850 kPa Expansion Control Valve |
| LVRA20-350 |
350 kPa |
Use with 500 kPa Expansion Control Valve |
| LVRA20-500 |
500 kPa |
Use with 850 kPa Expansion Control Valve |
| LVRA20-600 |
600 kPa |
Use with 850 kPa Expansion Control Valve |
Note: All limiting valves must be protected by a downstream expansion valve of the relative
setting as prescribed in the table above. |