Pressure Limiting Valve
Application

High (mains) pressure systems.

Video
Limiting Stop Valve.
Run-time: 50 seconds

Requires Windows Media Player to be installed.

Standards
  • Complies with NZ Building Code G12 (2001)
  • Complies with NZS 4608
  • Patent No. 280678
  • LVA - AS1357.2-1998, Lic. 2596
  • LVRA20 - AS1357.2 Lic. 2596
Specifications

LV15 Inlet 15mm, 1/2" BSP (male)
Outlet 20mm, 3/4" BSP (male)
LV20 Inlet 20mm, 3/4" BSP (female)
Outlet 20mm, 3/4" BSP (male)
LVT15 Inlet 15mm, 1/2" BSP (male)
Outlet 20mm, 3/4" BSP (male)
LVT20 Inlet 20mm, 3/4" BSP (female)
Outlet 20mm, 3/4" BSP (male)
LV25 Inlet 25mm, 1" BSP (male)
Outlet 25mm, 1" BSP (male)

LSV20 Inlet 20mm, 3/4" BSP (male)
Outlet 20mm, 3/4" BSP (male)

LVA Inlet 20mm, 3/4" BSP (female)
Outlet 20mm, 3/4" BSP (male)
LVRA Inlet 20mm, 3/4" BSP (female)
Outlet 20mm, 3/4" BSP (male)

Length LV  (all models except LV25) 80mm
LV25 110mm
LSV 140mm
LVRA 70mm
  • Maximum inlet pressure: 1600 kPa [230 P.S.I.] (LV25 up to 2000 kPa).
  • Maximum temperature: 65°C.
  • Pressure compensated to give constant outlet pressure regardless of inlet pressure.
  • Adjustable outlet pressure: 200 - 600 kPa [29 - 87 P.S.I.].
  • Removable cartridge for easy servicing.
  • Integral 60 mesh (250 micron) filter.
  • DR (Dezincification Resistant) brass.
Flow Chart


Installation
  • Refer to Technical Area for installation guide.
  • Do NOT install Limiting Valve in the ground.
  • Do NOT apply heat near valve during installation.
  • Install so that both hot and cold supplies are balanced.
  • Can be installed in any orientation. For external application, cartridge must be at bottom.
  • Must be installed with correct Expansion Valve fitted down stream of a limiting valve.
  • To adjust outlet pressure use large Philips/Pozi screw driver, turn adjusting screw clockwise to increase (1 turn = 60 kPa [9 P.S.I.]).
Removable Cartridge
  • All valve seats are contained within cartridge.
  • No need to remove body from valve train.
  • Unscrew cartridge to replace or clean filter.
  • Removal of cartridge will not affect set pressure.
Sectional Views

Pressure Limiting (LV-15 & LV-20)
Pressure Limiting (LV-25 only)
Pressure Limiting Stop Valve (LSV)
Pressure Limiting Replaceable (LVRA)








Brochure

Download the new LV25 Pressure Limiting Valve brochure as a PDF* or contact us to have one sent to you.



Download as PDF

*Requires Adobe Acrobat Reader to be installed.

Product Codes

LV15-350 350 kPa Use with EVT500
LV15-500 500 kPa Use with EVT700
LV20-350 350 kPa Use with EVT500
LV20-500 500 kPa Use with EVT700
LV25-500 500 kPa Use with EVT700
LVT15-350 350 kPa Use with EVT500
LVT15-500 500 kPa Use with EVT700
LVT20-350 350 kPa Use with EVT500
LVT20-500 500 kPa Use with EVT700
LSV20-350 350 kPa Use with EVT500
LSV20-500 500 kPa Use with EVT700
LVA20-350 350 kPa Use with 500 kPa Expansion Control Valve
LVA20-500 500 kPa Use with 850 kPa Expansion Control Valve
LVA20-600 600 kPa Use with 850 kPa Expansion Control Valve
LVRA20-350 350 kPa Use with 500 kPa Expansion Control Valve
LVRA20-500 500 kPa Use with 850 kPa Expansion Control Valve
LVRA20-600 600 kPa Use with 850 kPa Expansion Control Valve

Note: All limiting valves must be protected by a downstream expansion valve of the relative setting as prescribed in the table above.