Application
High pressure, solar and pumped plumbing systems.
Standards
- Complies with NZ Building Code G12 (2001)
- Complies with NZS 4607:1989
Specifications
- CP15 includes: Pressure Limiting Valve (LVT15-500), Cold Water Expansion Valve (EVT 700), Tempering Valve (TV20), 2 x Ball Valves, Non-Return (NR), and cap.
- CP20 includes: Pressure Limiting Stop Valve (LSV20-500), Cold Water Expansion Valve (EVT 700), Tempering Valve (TV20), 1 x Ball Valve, Non-Return (NR).
- CP20T - same as CP20 except has LVT not LSV.
- CP20S includes: Pressure Limiting Stop Valve (LSV20-500), Cold Water Expansion Valve (EVT 700), Solar Tempering Valve (TV20S), 1 x Ball Valve, Non-Return (NR) - Note: 350 kPa option available on request.
- CP20P (Pump Pack) includes: Filterstop (FS20), Cold Water Expansion Valve (EVT 700), Tempering Valve (TV20), Ball Valve, Non-Return (NR) For use where no Pressure Limiting Valve required, e.g. pump applications.
- CP20M (Manifold Pack) includes: Pressure Limiting Stop Valve (LSV20-500), Cold Water Expansion Valve (EVT 700), Tempering Valve (TV20), 1 x Ball Valve, Non-Return (NR), 100mm crox connector.
|
 |
 |
 |



Product Codes
| CP15 |
15mm - Inlet Limiting Valve |
| CP20 |
20mm - Limiting Stop Valve |
| CP20T |
20mm - Take-off on Limiting Valve |
| CP20S |
20mm - Solar Tempering Valve |
| CP20P |
20mm - Pump Pack |
| CP20M |
20mm - Manifold Pack |
| CP15NTV |
15mm - No Tempering Valve |
|