TechnicalContact Us

Isolating Non-Return Valve
Application
  • Low and high (mains) pressure systems.
  • Any application where an isolating valve and non return valve is required.
Standards
  • Complies with NZ Building Code G12 (2001)
  • Complies with NZS 4608:1992
  • Certified to AS1357.1 & AS1357.2 Lic 2596
Specifications

INR-15 Inlet 15mm, 1/2" BSP (female)
Outlet 15mm, 1/2" BSP (female)
Length 70mm

  • Non-return check valve cartridge
  • Maximum inlet pressure: 1600 kPa [230 P.S.I.]
  • Maximum temperature: 60˚C
  • DR (Dezincification Resistant) brass.
Flow Chart


Installation
  • Refer to Technical Area for installation guide.
  • Can be installed in any orientation but is best with filter bowl down for ease of cleaning.
  • Do NOT install in the ground.
  • Do NOT apply heat near the valve during installation.
Sectional View


Product Codes

INR15 15mm


Design by Burning Chrome© APEX Valves Limited.PrivacyWarranty